Wiring the INJ-24’s Power Outputs
The two left-most contacts of the 3-contact terminal block connector on
the INJ-24s top panel are used for 24 VDC output. Top and front views of
one of the terminal block connectors are shown here.
STEP 1:
Insert the negative/positive DC wires into the V-
/V+
terminals.
STEP 2:
To keep the DC wires from pulling loose, use a small
flat-blade screwdriver to tighten the wire-clamp
screws on the front of the terminal block connector.
STEP 3:
Insert the plastic terminal block connector prongs
into the terminal block receptor, which is located on
INJ-24’s top panel.
LED Indicators
Several LED indicators are located on the ING-24’s front panel. The
function of each LED is described in the table below.
LED
Color
State
Description
Power AMBER
On
Power is being supplied
Off
Power is not being supplied
PoE AMBER On Power is being supplied to a Powered
Device (PD)
Off Power is not being supplied to a Powered
Device (PD)
Specifications
Technology
Standards IEEE802.3, 802.3u, 802.3ab, 802.3af, 802.3at
Interface
RJ45 Ports 10/100/1000BaseT(X) speed
LED Indicators Power, PoE
Power
Input Voltage 24/48 VDC (20 to 60 VDC)
Input Current Max. 1.3 A (@ 24 VDC)
Connection Removable 3-pin terminal block
Overload Current
Protection
1.6 A
Reverse Polarity
Protection
Present
PoE (per port)
Maximum Output Power 30 W
Mechanical
Housing IP30 protection, plastic case
Dimensions 25 × 109 × 88 mm (0.98 x 4.29 x 3.46 in)
Weight 115 g
Installation DIN-Rail, wall mounting