Moxa Industrial Media Converter
IMC-101G
Hardware Installation Guide
Second Edition, August 2009
© 2009 Moxa Inc. All rights reserved.
Reproduction without permission is prohibited.
Fl.4, No.135, Lane 235, Pao-Chiao Rd. Shing Tien City, Taipei, Taiwan,
R.O.C.
TEL: +886-2-8919-1230
P/N: 1802001014011
Vue de la page 0
1 2 3 4 5 6 ... 14 15

Résumé du contenu

Page 1 - Hardware Installation Guide

Moxa Industrial Media Converter IMC-101G Hardware Installation Guide Second Edition, August 2009 © 2009 Moxa Inc. All rights

Page 2 - Features

- 10 -1000BaseT Ethernet Port Connection 1000BaseT data is transmitted on differential TRD+/- signal pairs over copper wires. MDI/MDI-X Port Pinouts

Page 3

- 11 -Redundant Power Inputs Both power inputs can be connected simultaneously to live DC power sources. If one power source fails, the other live s

Page 4 - Dimensions

- 12 -LED Indicators The front panel of the IMC-101G has several LED indicators. The function of each LED is described in the table below. LED Colo

Page 5 - Wall Mounting (Optional)

- 13 -Dual Speed Functionality and Switching The IMC-101G’s 10/100/1000 Mbps RJ45 switched port auto negotiates with the connected device for the fa

Page 6 - ATEX Information

- 14 -Optical Fiber: 1000BaseSX/LX/LHX/ZX Distance Multi mode: 1000BaseSX: 0 to 500 m, 850 nm (50/125 µm, 400 MHz*km) 0 to 275 m, 850 nm (62.

Page 7 - Grounding the IMC-101G

- 15 -Serial Number The serial number of a product is made up of 12 alphanumeric characters and includes the region in which the product was manufac

Page 8 - Wiring the Alarm Contact

- 2 -Overview Moxa’s IMC-101G industrial gigabit media converter is designed for reliable and stable operation in harsh industrial environments, and

Page 9 - Connection

- 3 -Panel Layouts of IMC-101G Series Top Panel ViewV1 V2 INPUTS: 24 VDCPWR2V2+V2-V1-V1+FAULTPWR1123PIDNOPORT ALARM3124Rear Panel View151615Front Pa

Page 10 - 1000BaseSFP Fiber Port

- 4 -Dimensions Din-Rail AttachmentPanel Mounting KitRear Panel8.8018.0044.0030.5018.0030.504632.118.230.5031.904618.232.1105.009.00134.0063.83M386.

Page 11 - DIP Switch Setting

- 5 -DIN-Rail Mounting The aluminum DIN-Rail attachment plate should be fixed to the back panel of the IMC-101G when you take it out of the box. If

Page 12 - Auto MDI/MDI-X Connection

- 6 -STEP 2: Mounting the IMC-101G on the wall requires 4 screws. Use the IMC-101G, with wall mount plates attached, as a guide to mark the correct

Page 13 - Dual Speed Functionality and

- 7 -Wiring Requirements WARNING Do not disconnect modules or wires unless power has been switched off or the area is known to be non-hazardous. The

Page 14

- 8 -ATTENTION This product is intended to be mounted to a well-grounded mounting surface such as a metal panel. Wiring the Alarm Contact The Alarm

Page 15 - Serial Number

- 9 -ATTENTION Before connecting the IMC-101G to the DC power inputs, make sure the DC power source voltage is stable. Communication Connections All