Moxa M-1401 Manuel Page 78

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 129
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 77
ioLogik MXIO DLL API Reference Direct I/O Command Sets
6-41
Pulse2K_SetSafeValues
This function code is used to set the safe value.
C/C++
Arguments
Return Value
int Pulse2K_SetSafeValues ( int hConnection,
BYTE bytStartChannel,
BYTE bytCount,
DWORD dwValue);
hConnection: The handle for an I/O connection.
bytStartChannel: Specifies the starting channel.
bytCount: The number of channels to set.
dwValue: Stores the safe value, each bit holds the value
of one channel. A bit value of 0 represents the
safe value of the start channel. A bit value of 1
represents the value of the second pulse
channel. The values are:
0: stop
1: start
Succeed MXIO_OK.
Fail Refer to Return Codes.
Pulse2K_GetSafeValue
This function code is used to get the safe value for a specific pulse
channel.
C/C++
Arguments
Return Value
int Pulse2K_GetSafeValue( int hConnection,
BYTE bytChannel,
BYTE * bytValue);
hConnection: The handle for an I/O server connection.
bytChannel: The desired channel.
bytValue: A pointer to the specific pulse channel’s
power on value. The values are:
0: stop
1: start
Succeed MXIO_OK.
Fail Refer
t
oRe
t
u
r
nCodes.