AWK-5222 User’s Manual Software Installation/Configuration
5-3
2. Select Open under Port Manager to open a new connection.
3. The Communication Parameter page of the Property window opens. Select the appropriate
COM port for Console Connection, 115200 for Baud Rate, 8 for Data Bits, None for Parity,
and 1 for Stop Bits.
4. Click on the Terminal tab, and select VT100 (or ANSI) for Terminal Type. Click on OK to
continue.
5. The Console login screen will appear. Log into the RS-232 console with the login name
(default: admin) and password (default: root, if no new password is set).