- 9 -
ATTENTION
This product is intended to be supplied by a Listed Power Unit
marked “Class 2” or “LPS” and rated O/P: 12 to 48 VDC, minimum
6 W (12 V/0.494 A to 48V/0.121 A, 25°C).
Make sure External Power Adaptor (includes power cords and
plug assemblies) provided with the unit is certified and suitable
for use in your country.
Before connecting the AWK-
4131 to the DC power inputs, make
sure the DC power source voltage is stable.
ATTENTION
Do not use the PoE Injector. Instead, please use an
IEEE802.3af
or IEEE802.3at compliant PSE (Power Sourcing Equipment) for
PoE (Power over Ethernet) device.
Wiring the Digital Inputs and Relay Contact
(Digital Output)
The AWK-4131 has two sets of digital inputDI1 and DI2. Each DI
comprises two contacts of the 8-pin M12 connector on the AWK-4131’s
bottom panel. These two digital inputs can be connected to
digital-output-enabled sensors for on-site status monitoring.
The AWK-4131 also has one relay output, which consists of the two
contacts. These relay contacts are used to detect user-configured events.
The two wires attached to the Relay contacts form an open circuit when a
user-configured event is triggered. If a user-configured event does not
occur, the Relay circuit will be closed.
A field-installable plug, M12A-8PF-IP67, is recommended for
connecting the AWK-4131’s DIs and relay.
Pin Signal
1
Relay
2
3 DI1 I1
4 DI1 COM_1
5 DI2 I2
6 DI2 COM_2
7
Reserved
8